Products
Blood And Fluid Warmer
Bio-X is the authorized channel partner for Blood Warmer from Keewell Medical Technology. The Blood and Infusion Warmer can be used in all cases in which hypothermia of the patient through cold transfusions and infusion solutions is to be prevented. The intelligent control circuit of the device operates and deals with the temperature signal that is sent by high-precision sensor, and continually adjusts heating state, in order to rapidly keep the surface temperature of the heat exchanger at the set temperature. At the same time, the heat is transferred into the flowing liquid in the tubing that is placed in the grooves of the heat exchanger, to increase the temperature of the liquid. There are dual independent temperature protections inside the device to ensure the security of use.
FT 2800, FT 1800 & FT 800 comes with an external warming profile for better accuracy. QW618 requires a special extra-long IV set
![](https://www.biox.co.in/wp-content/uploads/2024/09/ttt.png)
![](https://www.biox.co.in/wp-content/uploads/2024/09/tt2.png)
![](https://www.biox.co.in/wp-content/uploads/2024/09/ttt4-317x1024.png)
![](https://www.biox.co.in/wp-content/uploads/2024/09/tt3-1024x1024.jpg)
![](https://www.biox.co.in/wp-content/uploads/2024/09/ttt45.png)
Model | FT2800 | FT1800 | FT800 | QW618 | QW3 |
Temperature Setting | 33°C-41°C | 33-41°C | 39°C | 37°C-42°C | 37°C-42°C (0.1°C increments) |
Power Supply | AC 100~240 V / 50-60 Hz | AC 230 V/ 50-60 Hz | AC 230 V/ 50-60 Hz | AC 230 V ± 10% 50-60 Hz | AC 230 V/ 50-60 Hz |
Power Consumption | Max. 180VA | Max. 120VA | Max. 120VA | Max. 250VA | Max. 80VA |
Type Of Protection Against Electric Shock | Class I | Class I | Class I | Class I | Class I |
Degree Of Protection Against Electric Shock | BF Applied Part, Defibrillation- Protected | BF Applied Part, Defibrillation Protected | BF Applied Part, Defibrillation Protected | Type B | BF Applied Part, Defibrillation Protected |
Defibrillation | Protected | Protected | Protected | Protected | Protected |
Degree Of Protection Against Ingree Of Liquids | IPX2 | IPX2 | IPX2 | IPX4 Splash Proof | 1PX1 |
Temperature Accuracy | + 1.0°C | ± 1.0°C | ± 1.0°C | ± 0.5°C | ± 1.0°C |
Overheat Protection | 42°C/43°C | 42°C/43°C | 42°C/43°C | 43°C/ 45°C /48±3°C | 43/45/48±3 |
Low Temperature Alarm | 32°C | 32°C | 33°C | 36°C | 36°C |
Warming Up Time | From 20°C to 36°C Approx. 2min. | From 20°C to 36°C Approx. 2min. | From 20°C to 36°C Approx. 2min. | <45 sec (20°C-30°C) | From 20°C to 36°C Approx. 2min. |
Operating Mode | Continuous | Continuous | Continuous | Continuous | Continuous |
Dimensions | 200x130x250 mm | 85x 65×175 | 85x 65×175 mm | 100x170x210 mm | 85x 65×175 mm |
Weight | 2.30Kg | 1.20Kg | 1.20Kg | 1.30Kg | 0.7kg |
Warming Profile | Length 1400 mm; Compatible to IV Tube 3.5-5.0 mm O.D | Length 1400 mm; Compatible to IV Tube 3.5-5.0 mm O.D | Length 1400 mm; Compatible to IV Tube 3.5-5.0 mm O.D. | NA | NA |
Flow Rate | Individual Warming Profile- 1.5L/H Both Warming Profiles Combined 3L/H | 1.5L/H | 1.2L/H | 6L/H | IL/H |